Description

Masterdeck PU-200 is an economical, water-borne environmentally friendly, two pack car park floor coating which is an extremely tough and durable coating with excellent wear resistance.  It has excellent chemical and solvent resistance making it suitable for many application areas.  Due to its high cross-linkage provides a good stain resistance surface which allows for easy cleaning.  It has excellent UV stability and non-yellowing properties.

Purpose

Suitable for both interior and exterior applications.

Main Benefits

  • Water-borne, so environmentally friendly.
  • Good wear resistance.
  • Fast drying.
  • Excellent coverage rates.
  • Easy to apply.
  • Low odour.
  • Long over-coating window.
  • Non-yellowing.
  • Compliant with health & safety regulations.

Coverage

This 10 litre pack will cover 100 square metres.

Preparation

Uncoated concrete, masonry or tile surfaces

Any loose and flaking material needs to be removed.

Thoroughly clean to remove dirt, grease and contaminants. Do not apply to wet or damp substrates.

Do not apply in temperatures below 10°C or above 35°C relative humidity should not exceed 90%.

For smooth concrete mechanically sand to provide a suitable key. Thoroughly remove all dust.

Unpainted floors should be sealed, please contact us for recommended sealer.

Previously painted surfaces

For loose, flaking or otherwise defective areas, carefully remove to a firm edge.  Thoroughly clean to remove dirt, grease and contaminants. Do not apply to wet or damp substrates.  Abrade gloss-coated surfaces to provide a key.  Do not apply in temperatures below 10°C or above 35°C relative humidity should not exceed 90%.

Pre-testing

Always test the type of surface to ensure suitability and desired result. Apply a test area according to the

following application procedures. Test cross hatch adhesion to substrate to ensure adequate adhesion.  Contact us if further advice if required.

Mixing

Mix components activator into base and thoroughly mix for 4 minutes using an electric drill with a paddle attachment, on a slow speed setting. 

Application Conditions

Min ambient temperature: 8°C

Min substrate temperature: 8°C

Max substrate temperature: 40°C

Max relative humidity: 60%

Recommended optimum conditions for speedy drying:

Ambient temperature 20°C at relative humidity below 45%.

Application Instructions

Follow surface preparation instructions and ensure application conditions have been met.

For best application apply FloorTec PU-200 apply with a medium pile roller.

Airless or air assisted airless spray equipment, conventional or HVLP air assisted spray is also suitable,

but the paint may need to be thinned with up to 10% water.

A good quality bush can also be used.

Do not apply if there is a risk of rain, fog or other precipitation, and ensure application conditions are

maintained after application and until the coating has fully cured.

If a second coat is required please see recoat times stated in the Product Information section.

Clean Up

Equipment should be cleaned immediately with cold water.

Dried paint may be removed with aromatic or oxygenated solvents.

Storage

Store between 5°C and 30°C.

Maximum storage period is 6 months in original containers.

Packaging

10 litres packed in 2 x 5 litre kits (each 5 litre kit will contain a resin component and a hardener component).

Safety Information

Wear suitable protective clothing. Avoid splashing onto bare skin and eyes.

Always refer to the Health and Safety Data Sheet before use.

 

General  Properties

 

Density (S.G.)

ISO 2811-1

Approx. 1.1 – 1.3 kg/l (Depending on the colour)

 

Solids Content

Theoretical

 

Approx. 60% Volume Solids

 

Mechanical Properties

 

Recommended Thickness

ISO 2808

 

100 - 170 μm WFT

60 - 100 μm DFT

 

Coverage Rate

Theoretical

10 sqm per 1 litre at 60 μm DFT dependent upon the porosity of the substrate and application method

 

Recoat Time

Theoretical

Minimum 4 hours - Maximum 7 days

 

Pot Life

 

Approximately 3 Hours @ 25°C

 

 

Application

Method

Thinning

Tip Size

Spray

Pressure

Number

of Coats

WFT Per

Coat

DFT Per

Coat

Coverage Per

Coat

 

Airless Sprayer

NA

13 - 15

 

thou

1700 -

2200 psi

1

100 - 170 microns

60 - 100 microns

10 sq. metres per 1 litre at 100 μm WFT

Conventional

 

or HVLP

5 - 10%

cold water

as required

1.6 - 1.8

 

mm

30 - 90 psi

1 - 3

100 - 170 microns

60 - 100 microns

10 sq. metres per 1 litre at 100 μm WFT

Roller Medium pile

NA

NA

NA

2

100 - 170 microns

60 - 100 microns

10 sq. metres per 1 litre at 100 μm WFT

Limitations

This water based product will blead through standard masking tape, therefore water resistant masking tape should be used.